²úÆ··ÖÀà+
IEC61850ͨÐÅÐÒé¼òÊö
²âÊÔ¹¤¾ß£º²ÉÓÃIecClient½øÐÐÖðÏ¸ÇIEC61850¿âÖеŦÄÜ£¬ÓÈÆäÊÇ76net±ØÓ®¹ÙÍøÊÖ»ú°æÊ¹Óõ½µÄ¹¦ÄÜ£¬Èçµã»÷»ñÈ¡Êý¾ÝµÄÖµ£¬»òÕßÉèÖÃÊý¾ÝµÄÖµ
ʹÓà mms_ethereal½Ø°ü·ÖÎöÕë¶ÔÐÔ²âÊÔ£ºÕë¶ÔIEC61850¿âµÄÄ³Ð©ÌØÊ⹦ÄÜ£¬¿ÉÒÔΪÆä±àдµ¥¶ÀÏÂλ»ú³ÌÐòºÍרÃŵÄxmlÎļþ¡£ÕâÖÖ²âÊÔÐèÒªwinceµÄÓ¦Óÿª·¢»·¾³£¬ÒÔ¼°¶Ô¿â¹¦ÄܺÍʹÓñȽÏÊìϤ
IEC61850-MMSÕûÌå½á¹¹£º
(1) ºÍÆäËûͨÐÅÐÒéÒ»Ñù£¬IEC61850Ò²¿É·ÖΪ·þÎñÆ÷ºÍ¿Í»§¶ËÁ½²¿·Ö£¬·þÎñÆ÷Ìṩ¶ÔÓ¦µÄ·þÎñ£¬¿Í»§¶ËÔòÇëÇó·þÎñ
(2) ·þÎñÆ÷ºÍ¿Í»§¶ËµÄ»®·Ö¶¼Ö»ÊÇÂß¼Éϵ쬲¢²»¹æ¶¨ËûÃǵÄÎïÀíλÖã¬Í¬Ò»Ì¨É豸£¬¿ÉÄܼȾßÎñ·þÎñÆ÷µÄ¹¦ÄÜ£¬ÓÖ¾ßÎñ¿Í»§¶ËµÄ¹¦ÄÜ
(3) ·þÎñÆ÷ºÍ¿Í»§¶ËµÄͨÐÅÒ²¸ß¶È³éÏ󣬲»¹æ¶¨·þÎñ¾ßÌåÔõÑù±»µ÷Óõģ¬Ö»¹æ¶¨ÁË·þÎñ½Ó¿Ú£¬½Ó¿ÚµÄʵÏÖÓÉϵͳ¾ö¶¨(¿ÉÒÔΪUSB¡¢Ethernet¡¢µ±·þÎñÆ÷ºÍ¿Í»§¶ËλÓÚͬһ̨»úÆ÷ÉÏÒ²¿ÉÖ±½Ó½øÐÐÄڴ濽±´)µ±Ç°´ó²¿·ÖÒÔEhternetΪÖ÷IEC61850-MMSÐÒé·Ö²ã£º
(1) MMSλÓÚISOÆß²ãÄ£Ð͵ÄÓ¦Óò㣬Æä¸ß¶È³éÏó£¬ÎªÁ˱ãÓÚÀí½â£¬76net±ØÓ®¹ÙÍøÊÖ»ú°æ¿ÉÒÔ½«Æä·ÖΪÁ½²ã£ºASCI²ã(Abstract Service Communication Interface)¡¢MMS²ã(Manufacturing Message Specification)
(2) ASCI(Abstract Service Communication Interface)²ã¶¨ÒåÁËϵͳµÄÂß¼¹¦ÄÜ,È磺һ¸öÉ豸ÖÐÓжàÉÙ¸öÂß¼É豸¡¢¶àÉÙ¸öÂß¼½Úµã£¬Ã¿¸öÂß¼½ÚµãµÄÊôÐÔÒÔ¼°ÆäÖ§³ÖµÄ·þÎñ¡£
(3) ASCI(Abstract Service Communication Interface)²ã²»¹ØÐĿͻ§ºÍ·þÎñÆ÷ÔõôͨÐÅ£¬Ö»¹ØÐÄ·þÎñÆ÷ÓÐÄÄЩ¹¦ÄÜ¿ÉÒÔµ÷Óã¬ÄÄЩÊý¾ÝÊôÐÔ¿ÉÒÔ»ñÈ¡£¬ÄÄЩ½Úµã¿ÉÒÔ¿ØÖÆ
(4) MMS²ã(Manufacturing Message Specification)¶¨ÒåÁË´ÓASCIµ½¾ßÌåÍøÂçͨÐŵÄÓ³Éä
(5) MMS²ã(Manufacturing Message Specification)²»¹æ¶¨Í¨ÐÅÍøÂçÀàÐÍ£¬Ò²²»¹æ¶¨Í¨ÐÅÖ¡µÄ¾ßÌå¸ñʽ£¬Ö»¹æ¶¨Í¨ÐÅÖ¡µÄ¹¦ÄÜ£¬Í¨ÐÅģʽ
(6) Èç: MMS¹æ¶¨ÁËÒ»¸öͨÐÅÖ¡Ðè°üº¬ÄÄЩÄÚÈÝ£¬ÕâЩÄÚÈÝ´ú±íʲôÒâÒ壬¶ø²»¹æ¶¨ÕâЩÄÚÈÝÒÔʲôÊý¾ÝÐÎʽÔÚÍøÂçÉÏÌåÏÖ£¬Òò´Ë¿ÉÒÔ²ÉÓò»Í¬µÄÊý¾Ý¸ñʽÔÚ¸÷ÖÖÍøÂçÉÏʵÏÖ£¬µ«ÊÇ·þÎñºÍ¿Í»§¶ËҪʹÓÃͬÑùµÄÊý¾Ý¸ñʽºÍÍøÂçÀàÐÍIEC61850ͨÐÅÄ£ÐÍ
(1) IEC61850ͨÐű¨ÎÄÓÉÒÔÏÂ6À౨ÎÄ×é³É£ºÀàÐÍ1(¿ìËÙ±¨ÎÄ)¡¢ÀàÐÍ1A(ÌøÕ¢±¨ÎÄ)¡¢ÀàÐÍ2(ÖеÈËٶȱ¨ÎÄ)¡¢ÀàÐÍ3(µÍËÙ±¨ÎÄ)¡¢ÀàÐÍ4(ÔʼÊý¾Ý±¨ÎÄ)¡¢ÀàÐÍ5(Îļþ´«Ê书ÄÜ)¡¢ÀàÐÍ6(ʱ¼äͬ²½±¨ÎÄ)
(2) ²»Í¬ÀàÐ͵ı¨ÎÄÓÉÓÚÆäÊôÐÔ(È磺Êý¾ÝÁ¿¡¢ÖØÒªÐÔ¡¢ÊµÊ±ÐÔ)²»Í¬¶øÊ¹Óò»Í¬µÄ´«Êäģʽ
(3) 1ºÍ1AÀ౨ÎÄÓÉÓÚÆäʵʱÐÔÒªÇó¸ßËùÒÔ±»Ó³ÉäΪרÃŵÄÒÔÌ«ÍøÀàÐÍ
(4) 2¡¢3¡¢5ÀàÐͱ¨ÎÄÔòʹÓÃÒ»°ãµÄTCP/IPÐÒé
(5) ÀàÐÍ6±¨ÎÄÓÉÓÚÆäÊý¾ÝÁ¿´ó¡¢ÊµÊ±ÐÔÒªÇ󲻸ߣ¬¿ÉÒÔºÍ2¡¢3¡¢5±¨ÎÄÇø·Ö¿ªÀ´
(6) ´ËÍâIEC61850Öл¹²ÉÓÃÁËÆäËû·Ç±ê×¼ÐÒ飬ÈçÓÃÓÚʱ¼äͬ²½µÄSNTPÐÒé
(7) IEC61850²ÉÓõÄÐÒé·ÖÀàÈçÏÂ: ²ÉÑùÖµ(×é²¥) ¡ª SMV(IEC61850-9-2)¡¢Í¨Óñäµçվʼþ ¡ª GOOSE¡¢Ê±¼äͬ²½ ¡ª SNTP¡¢ºËÐÄACSI·þÎñ ¡ª MMS Protocol Sutie¡¢Í¨Óñäվ״̬ʼþ ¡ª GSSE×ܽá
(1) ×ܵÄÀ´Ëµ¡¢IEC61850µÄͨÐÅ¿ÉÒÔ·ÖΪÈçÏÂÁ½ÖÖģʽ
(2) ÆÕͨ±¨ÎÄ£¬Ê¹ÓÃTCP/IPÕâÀàÓÐÁ¬½ÓµÄÐÒéʵÏÖ£¬ÆäÌØµãÊÇ£ºÄÜÐÅÎȶ¨¡¢Êý¾ÝÁ¿´ó£¬¶àΪ¶Ëµ½¶ËͨÐÅ¡£±¨ÎIJÉÓÃÒ»²¿Ò»´ðµÄ·½Ê½¶ÁÈ¡¡¢É豸ºÍ½øÐпØÖÆ
(3) ¿ìËٺͽô¼±±¨ÎÄ£¬Ò»°ãʹÓÃÎÞÁ¬½ÓµÄÐÒéʵÏÖ£¬¿ÉÒÔÊǶಥ£¬Ò²¿ÉÒÔÊǵ¥²¥£¬ÕâÀ౨ÎIJ¢²»Ò»¶¨ÓлØÓ¦£¬ÆäÌØµãÊÇʵʱÐԸߡ£²ÉÓÃÁíÍâµÄ·½·¨(ÈçÔö¼Ó´ø¿í¡¢Ö±½ÓÓëÁ´Â·²ãͨÐÅ)µÄ°ì·¨ÊµÏÖ±¨ÎĵĿɿ¿ÐÔ£¬Ò»°ãÇé¿öÏÂ
ÕâÀ౨ÎÄÿ¹ýÒ»¶Îʱ¼ä·¢ËÍÒ»´Î£¬·þÎñÆ÷Ò»Ö±ÔÚ¼àÌý£¬ÔÚÒ»¶Îʱ¼äºó»¹Ã»½ÓÊܵ½Ä³Ò»¿Í»§·¢¹ýÀ´µÄ±¨ÎÄ£¬ÔòÈÏΪ¸Ã¿Í»§¶ËÒÑÀëÏߣ¬ÔÚ¿Í»§¶ËÓÐÌØÊâʼþʱ£¬¿Í»§¶ËÔò»áÌá¸ß±¨ÎÄ·¢ËÍÆµÂÊ