±äµçÕ¾×Ô¶¯»¯¼¼Êõ·¢Õ¹ºÜ¿ì£¬¹úÄÚÍâ³§ÉÌÏà¼ÌÍÆ³öÁ˶àÖÖ±äµçÕ¾×Ô¶¯»¯ÏµÍ³²úÆ·¡£ÎªÊ¹²»Í¬³§É̵IJúÆ·¾ßÓл¥²Ù×÷ÐÔ£¨interoperation£©£¬IECÒÑÖÆ¶¨¹ØÓÚ±äµçÕ¾×Ô¶¯»¯ÏµÍ³µÄͨÐÅÍøÂçºÍϵͳµÄ¹ú¼Ê±ê×¼IEC 61850¡£¾¡¹ÜIEC 61850ÏÖÔÚÖ»Äâ³öÁËίԱ»á²Ý°¸£¬»¹Ã»Óй«²¼Õýʽ°æ±¾£¬µ«Ñо¿ºÍ·ÖÎöÆäÌØµã£¬¶ÔÓÚ76net±ØÓ®¹ÙÍøÊÖ»ú°æÁ˽â±äµçÕ¾×Ô¶¯»¯¼¼Êõ·¢Õ¹µÄ¹ú¼Ê´óÇ÷ÊÆºÍÉè¼ÆÐÂϵͳ»¹ÊǺÜÓÐÒæ´¦µÄ¡£±¾ÎĽ«¶ÔIEC 61850ͨÐÅÌåϵ×ö¼òÒªµÄ·ÖÎöºÍ½éÉÜ¡£
1¡¡IEC 61850µÄÀúÊ·±³¾°ºÍ×é³É
¡¡¡¡ÎªÊÊÓ¦±äµçÕ¾×Ô¶¯»¯¼¼ÊõµÄѸËÙ·¢Õ¹£¬1995Äê¹ú¼Êµç¹¤Î¯Ô±»áµÚ57¼¼ÊõίԱ»á£¨IEC TC57£©Îª´Ë³ÉÁ¢ÁË3¸ö¹¤×÷×é10£¬11£¬12£¨WG10/11/12£©£¬¸ºÔðÖÆ¶¨IEC 61850±ê×¼¡£¹¤×÷×é³ÉÔ±·Ö±ðÀ´×ÔÅ·ÖÞ¡¢±±ÃÀºÍÑÇÖÞ¹ú¼Ò£¬ËûÃÇÓеçÁ¦µ÷¶È¡¢¼Ìµç±£»¤¡¢µç³§¡¢²Ù×÷ÔËÐм°µçÁ¦ÆóÒµµÄ¼¼Êõ±³¾°£¬ÆäÖÐÓÐЩ³ÉÔ±²Î¼Ó¹ý±±ÃÀ¼°Å·ÖÞһЩ±ê×¼µÄÖÆ¶¨¹¤×÷¡£3¸ö¹¤×÷×éÓÐÃ÷È·µÄ·Ö¹¤£ºµÚ10¹¤×÷×鸺Ôð±äµçÕ¾Êý¾ÝͨÐÅÐÒéµÄÕûÌåÃèÊöºÍ×ÜÌ幦ÄÜÒªÇó£»µÚ11¹¤×÷×鸺ÔðÕ¾¼¶Êý¾ÝͨÐÅ×ÜÏߵ͍Ò壻µÚ12¹¤×÷×鸺Ôð¹ý³Ì¼¶Êý¾ÝͨÐÅÐÒéµÄ¶¨Òå¡£Õâ3¸ö¹¤×÷×é²Î¿¼ºÍÎüÊÕÁËÒÑÓеÄÐí¶àÏà¹Ø±ê×¼£¬ÆäÖÐÖ÷ÒªÓУº¢ÙIEC 870¡ª5¡ª101Ô¶¶¯Í¨ÐÅÐÒé±ê×¼£Û1£Ý£»¢ÚIEC 870¡ª5¡ª103¼Ìµç±£»¤ÐÅÏ¢½Ó¿Ú±ê×¼£Û2£Ý£»¢ÛUCA 2.0£Û3£Ý£¨utility communication architecture 2.0)£¬ÓÉÃÀ¹úµç¿ÆÔºÖƶ¨µÄ±äµçÕ¾ºÍÀ¡ÏßÉ豸ͨÐÅÐÒéÌåϵ£»¢ÜISO/IEC 9506ÖÆÔìÉÌÐÅÏ¢¹æ·¶MMS£Û4£Ý£¨manufacture message specification£©¡£
¡¡¡¡1999Äê3Ô£¬3¸ö¹¤×÷×éÌá³öÁËIEC 61850 ίԱ»á²Ý°¸°æ±¾£Û5£Ý¡£´Ó¸Ã°æ±¾¿´£¬IEC 61850±ê×¼¹²·ÖΪ10¸ö²¿·Ö£º
¡¡¡¡a. IEC 61850¡ª1¡¡»ù±¾ÔÔò£¬°üÀ¨IEC 61850µÄ½éÉܺ͸Åò¡£
¡¡¡¡b. IEC 61850¡ª2¡¡ÊõÓï¡£
¡¡¡¡c. IEC 61850¡ª3¡¡Ò»°ãÒªÇ󣬰üÀ¨ÖÊÁ¿ÒªÇ󣨿ɿ¿ÐÔ¡¢¿Éά»¤ÐÔ¡¢ÏµÍ³¿ÉÓÃÐÔ¡¢Çá±ãÐÔ¡¢°²È«ÐÔ£©£¬»·¾³Ìõ¼þ£¬¸¨Öú·þÎñ£¬ÆäËû±ê×¼ºÍ¹æ·¶¡£
¡¡¡¡d. IEC 61850¡ª4¡¡ÏµÍ³ºÍ¹¤³Ì¹ÜÀí£¬°üÀ¨¹¤³ÌÒªÇ󣨲ÎÊý·ÖÀà¡¢¹¤³Ì¹¤¾ß¡¢Îļþ£©£¬ÏµÍ³Ê¹ÓÃÖÜÆÚ£¨²úÆ·°æ±¾¡¢¹¤³Ì½»½Ó¡¢¹¤³Ì½»½ÓºóµÄÖ§³Ö£©£¬ÖÊÁ¿±£Ö¤£¨ÔðÈΡ¢²âÊÔÉ豸¡¢µäÐͲâÊÔ¡¢ÏµÍ³²âÊÔ¡¢¹¤³§ÑéÊÕ¡¢ÏÖ³¡ÑéÊÕ£©¡£
¡¡¡¡e. IEC 61850¡ª5¡¡¹¦ÄܺÍ×°ÖÃÄ£Ð͵ÄͨÐÅÒªÇ󣬰üÀ¨Âß¼½ÚµãµÄ;¾¶£¨access of logical nodes)£¬Â߼ͨÐÅÁ´Â·£¬Í¨ÐÅÐÅϢƬPICOM£¨piece of information for communication£©µÄ¸ÅÄ¹¦Ä͍ܵÒå¡£
¡¡¡¡f. IEC 61850¡ª6¡¡±äµçÕ¾×Ô¶¯»¯ÏµÍ³½á¹¹ÓïÑÔ£¬°üÀ¨×°ÖúÍϵͳÊôÐÔµÄÐÎʽÓïÑÔÃèÊö¡£
¡¡¡¡g. IEC 61850¡ª7¡ª1¡¡±äµçÕ¾ºÍÀ¡ÏßÉ豸µÄ»ù±¾Í¨ÐŽṹ¡ª¡ªÔÀíºÍģʽ¡£
¡¡¡¡h. IEC 61850¡ª7¡ª2¡¡±äµçÕ¾ºÍÀ¡ÏßÉ豸µÄ»ù±¾Í¨ÐŽṹ¡ª¡ª³éÏóͨÐÅ·þÎñ½Ó¿ÚACSI£¨abstract communication service interface£©£¬°üÀ¨³éÏóͨÐÅ·þÎñ½Ó¿ÚµÄÃèÊö£¬³éÏóͨÐÅ·þÎñµÄ¹æ·¶£¬·þÎñÊý¾Ý¿âµÄÄ£ÐÍ¡£
¡¡¡¡i. IEC 61850¡ª7¡ª3¡¡±äµçÕ¾ºÍÀ¡ÏßÉ豸µÄ»ù±¾Í¨ÐŽṹ¡ª¡ª¹«¹²Êý¾Ý¼¶±ðºÍÊôÐÔ£¬°üÀ¨³éÏ󹫹²Êý¾Ý¼¶±ðºÍÊôÐԵ͍Òå¡£
¡¡¡¡j. IEC 61850¡ª7¡ª4¡¡±äµçÕ¾ºÍÀ¡ÏßÉ豸µÄ»ù±¾Í¨ÐŽṹ¡ª¡ª¼æÈݵÄÂß¼½ÚµãºÍÊý¾Ý¶ÔÏóDO (data object)Ѱַ£¬°üÀ¨Âß¼½ÚµãµÄ¶¨Ò壬Êý¾Ý¶ÔÏó¼°ÆäÂ߼Ѱַ¡£
¡¡¡¡k. IEC 61850¡ª8¡¡ÌØÊâͨÐÅ·þÎñÓ³ÉäSCSM£¨special communication service mapping£©£¬µ½±äµçÕ¾ºÍ¼ä¸ô²ãÄÚÒÔ¼°±äµçÕ¾²ãºÍ¼ä¸ô²ãÖ®¼äͨÐÅÓ³Éä¡£
¡¡¡¡l. IEC 61850¡ª9¡¡ÌØÊâͨÐÅ·þÎñÓ³ÉäSCSM£¬¼´¼ä¸ô²ãºÍ¹ý³Ì²ãÄÚÒÔ¼°¼ä¸ô²ãºÍ¹ý³Ì²ãÖ®¼äͨÐŵÄÓ³Éä¡£
¡¡¡¡m. IEC 61850¡ª10¡¡Ò»ÖÂÐÔ²âÊÔ¡£
¡¡¡¡´ÓIEC 61850ͨÐÅÐÒéÌåϵµÄ×é³É¿ÉÒÔ¿´³ö£¬ÕâÒ»Ìåϵ¶Ô±äµçÕ¾×Ô¶¯»¯ÏµÍ³µÄÍøÂçºÍϵͳ×ö³öÁËÈ«Ãæ¡¢ÏêϸµÄÃèÊöºÍ¹æ·¶¡£
2¡¡IEC 61850µÄÌØµã
¡¡¡¡IEC 61850ÊǹØÓÚ±äµçÕ¾×Ô¶¯»¯ÏµÍ³µÄµÚ1¸öÍêÕûµÄͨÐűê×¼Ìåϵ¡£Ó봫ͳµÄͨÐÅÐÒéÌåϵÏà±È£¬ÔÚ¼¼ÊõÉÏIEC 61850ÓÐÈçÏÂÍ»³öÌØµã£º¢ÙʹÓÃÃæÏò¶ÔÏó½¨Ä£¼¼Êõ£»¢ÚʹÓ÷ֲ¼¡¢·Ö²ãÌåϵ£»¢ÛʹÓóéÏóͨÐÅ·þÎñ½Ó¿Ú£¨ACSI£©¡¢ÌØÊâͨÐÅ·þÎñÓ³ÉäSCSM¼¼Êõ£»¢ÜʹÓÃMMS¼¼Êõ£»¢Ý¾ßÓл¥²Ù×÷ÐÔ£»¢Þ¾ßÓÐÃæÏòδÀ´µÄ¡¢¿ª·ÅµÄÌåϵ½á¹¹¡£
3¡¡±äµçÕ¾×Ô¶¯»¯ÏµÍ³½Ó¿ÚÄ£ÐÍ
¡¡¡¡IEC 61850°´ÕÕ±äµçÕ¾×Ô¶¯»¯ÏµÍ³ËùÒªÍê³ÉµÄ¿ØÖÆ¡¢¼àÊӺͼ̵籣»¤Èý´ó¹¦ÄÜ´ÓÂß¼ÉϽ«ÏµÍ³·ÖΪ3²ã£¬¼´±äµçÕ¾²ã¡¢¼ä¸ô²ãºÍ¹ý³Ì²ã£¬²¢¶¨ÒåÁË3²ã¼äµÄ9ÖÖÂß¼½Ó¿Ú¡£IEC 61850¸ø³öµÄ±äµçÕ¾×Ô¶¯»¯ÏµÍ³½Ó¿ÚÄ£ÐÍÈçͼ1Ëùʾ¡£¹ý³Ì²ãÖ÷ÒªÍê³É¿ª¹ØÁ¿I/O¡¢Ä£ÄâÁ¿²ÉÑùºÍ¿ØÖÆÃüÁîµÄ·¢Ë͵ÈÓëÒ»´ÎÉ豸Ïà¹ØµÄ¹¦ÄÜ¡£¹ý³Ì²ãͨ¹ýÂß¼½Ó¿Ú¢ÜºÍ½Ó¿Ú¢ÝÓë¼ä¸ô²ãͨÐÅ¡£¼ä¸ô²ãµÄ¹¦ÄÜÊÇÀûÓñ¾¼ä¸ôµÄÊý¾Ý¶Ô±¾¼ä¸ôµÄÒ»´ÎÉ豸²úÉú×÷Óã¬ÈçÏß·±£»¤É豸»ò¼ä¸ôµ¥Ôª¿ØÖÆÉ豸¾ÍÊôÓÚÕâÒ»²ã¡£¼ä¸ô²ãͨ¹ýÂß¼½Ó¿Ú¢ÜºÍ½Ó¿Ú¢ÝÓë¹ý³Ì²ãͨÐÅ£¬Í¨¹ýÂß¼½Ó¿Ú¢ÛÍê³É¼ä¸ô²ãÄÚ²¿µÄͨÐŹ¦ÄÜ¡£±äµçÕ¾²ãµÄ¹¦ÄÜ·ÖΪ2ÀࣺһÊÇÓë¹ý³ÌÏà¹ØµÄ¹¦ÄÜ£¬Ö÷ÒªÖ¸ÀûÓø÷¸ö¼ä¸ô»òȫվµÄÐÅÏ¢¶Ô¶à¸ö¼ä¸ô»òȫվµÄÒ»´ÎÉ豸·¢Éú×÷ÓõŦÄÜ£¬ÈçĸÏß±£»¤»òȫվ·¶Î§ÄڵıÕËøµÈ£¬±äµçÕ¾²ãͨ¹ýÂß¼½Ó¿Ú¢àÍê³ÉͨÐŹ¦ÄÜ£»¶þÊÇÓë½Ó¿ÚÏà¹ØµÄ¹¦ÄÜ£¬Ö÷ÒªÖ¸ÓëÔ¶·½¿ØÖÆÖÐÐÄ¡¢¹¤³Ìʦվ¼°ÈË»ú½çÃæµÄͨÐÅ£¬Í¨¹ýÂß¼½Ó¿Ú¢Ù£¬¢Þ£¬¢ßÍê³ÉͨÐŹ¦ÄÜ¡£
ͼ1¡¡±äµçÕ¾×Ô¶¯»¯ÏµÍ³½Ó¿ÚÄ£ÐÍ
Fig.1¡¡The interface model of substation
automation system
¡¡¡¡IEC 61850µÄ·Ö²ãģʽÓëÏÖÓдó¶àÊý±äµçÕ¾×Ô¶¯»¯ÏµÍ³²»Í¬£¬ÔÚÏÖÓÐϵͳÖйý³Ì²ãµÄ¹¦Äܶ¼ÊÇÔÚ¼ä¸ô²ãÉ豸ÖÐʵÏֵģ¬ÓÚÊǾÍûÓжÀÁ¢µÄÂß¼½Ó¿Ú¢ÜºÍ½Ó¿Ú¢ÝÁË¡£Ëæ×ŹâµçÁ÷¡¢µçѹ»¥¸ÐÆ÷µÄʹÓã¬ÏÖ´úµçÁ¦¼¼ÊõµÄ·¢Õ¹Ç÷ÊÆÊǽ«Ô½À´Ô½¶àµÄ¼ä¸ô²ã¹¦ÄÜÏ·ŵ½¹ý³Ì²ãÖÐÈ¥¡£¿É¼û£¬IEC 61850ÊǸöÃæÏòδÀ´µÄ¿ª·ÅµÄ±ê×¼¡£
4¡¡Í¨ÐÅϵͳ½á¹¹
¡¡¡¡Èçͼ2Ëùʾ£¬IEC 61850ÃèÊöµÄͨÐÅÌåϵ´ÓÉϵ½ÏÂÓÉÈçϲ¿·Ö×é³É¡£
ͼ2¡¡IEC 61850ͨÐÅϵͳ×ÜÌå½á¹¹
Fig.2¡¡The general architecture of communication
system in IEC 61850
¡¡¡¡a. IEC 61850¡ª5¡£Õⲿ·ÖʹÓÃÃæÏò¶ÔÏó¼¼Êõ¶Ô±äµçÕ¾×Ô¶¯»¯ÏµÍ³µÄ¹¦ÄÜ¡¢×Ó¹¦ÄܽøÐÐÁË·ÖÀàºÍ¶¨Ò壬²¢ÒýÈëÁËÂß¼½ÚµãµÄ¸ÅÄÕâЩ¶ÔÓÚ·Ö²¼Ê½ÏµÍ³µÄÉè¼Æ¼°»¥²Ù×÷ÐÔÓÐÖØÒª×÷Óá£
¡¡¡¡b. IEC 61850¡ª7¡ª4¡£Âß¼½ÚµãLN£¨logical nodes£©Êǹ¹³Éϵͳ¹¦ÄܵĻù´¡£¬IEC 61850¡ª7¡ª4¶¨ÒåÁË»ù±¾Âß¼½ÚµãÀ༰ÆäÊý¾Ý¶ÔÏó¡£Í¼3ʾÒâÁËÊý¾ÝÄ£Ð͵IJã´Î½á¹¹£¬Í¼ÖÐ×î¸ß²ãÊDZê×¼»¯Á˵ÄÂß¼½ÚµãºÍÊý¾Ý¶ÔÏó¡£
ͼ3¡¡Êý¾ÝÄ£ÐͲã´Î
Fig.3¡¡The levels of data model
¡¡¡¡c. IEC 61850¡ª7¡ª3¡£Õⲿ·Ö¶¨ÒåÁËÂß¼½ÚµãËùʹÓõĻù±¾Êý¾ÝÀàÐÍ¡£
¡¡¡¡d. IEC 61850¡ª7¡ª2¡£Õⲿ·Ö¶¨ÒåÁ˳éÏóͨÐÅ·þÎñ½Ó¿Ú£¨ACSI£©¡£ACSI¶¨ÒåÁËÓëʵ¼ÊËùÓõÄͨÐÅÐÒéÎ޹صÄÓ¦Óã¬Ëü¶¨ÒåÁËÏà¹ØÍ¨ÐÅ·þÎñ¡¢Í¨ÐŶÔÏó¼°²ÎÊý¡£ACSIÌṩÈçÏÂ6ÖÖ·þÎñÄ£ÐÍ£ºÁ¬½Ó·þÎñÄ£ÐÍ£»±äÁ¿·ÃÎÊ·þÎñÄ£ÐÍ£»Êý¾Ý´«Êä·þÎñÄ£ÐÍ£»É豸¿ØÖÆ·þÎñÄ£ÐÍ£»Îļþ´«Êä·þÎñÄ£ÐÍ£»Ê±ÖÓͬ²½·þÎñÄ£ÐÍ¡£ÕâЩ·þÎñÄ£ÐͶ¨ÒåÁËͨÐŶÔÏóÒÔ¼°ÈçºÎ¶ÔÕâЩ¶ÔÏó½øÐзÃÎÊ¡£ÕâЩ¶¨ÒåÓɸ÷ÖÖ¸÷ÑùµÄÇëÇó¡¢ÏìÓ¦¼°·þÎñ¹ý³Ì×é³É¡£·þÎñ¹ý³ÌÃèÊöÁËij¸ö¾ßÌå·þÎñÇëÇóÈçºÎ±»·þÎñÆ÷ËùÏìÓ¦ÒÔ¼°²Éȡʲô¶¯×÷ÔÚʲôʱºòÒÔʲô·½Ê½ÏìÓ¦¡£ACSI¶¨ÒåµÄ·þÎñ¡¢¶ÔÏóºÍ²ÎÊýͨ¹ýÌØÊâͨÐÅ·þÎñÓ³É䣨SCSM£©Ó³É䵽ϲãÓ¦ÓóÌÐò¡£
¡¡¡¡e. IEC 61850¡ª8¡ªX/¡ª9¡ªX¡£¿¼Âǵ½TCP/IP¡¢OSI¡¢ÏÖ³¡×ÜÏߵȸ÷ÖÖ¸÷ÑùµÄͨÐÅϵͳÒѽ¨Á¢ÆðÀ´£¬IEC 61850ÒýÈëÁËÌØÊâͨÐÅ·þÎñÓ³É䣨SCSM£©¡£Èçͼ4Ëùʾ£¬SCSM½«³éÏóͨÐÅ·þÎñ¶ÔÏóºÍ²ÎÊýÓ³Éäµ½MMS£¬FMS£¬DNP»òIEC 870¡ª5µÈÓ¦Óò㡣ʵ¼ÊÉÏÕâÖÖÓ³ÉäµÄ¸´ÔÓÐÔÓëͨÐÅÍøÂçÓйأ¬Ä³Ð©ACSI·þÎñÒ²¿ÉÄܲ»±»ËùʹÓõÄÍøÂç¼¼ÊõËùÖ§³Ö¡£
IEC 61850¡ª8¡ª1¶¨ÒåÁËACSIµ½ISO/IEC 9506¼´MMSÖ®¼äµÄÓ³É䡣ͼ5¸ø³öÁËʾÒâͼ¡£
ͼ5¡¡ACSIµ½MMSÖ®¼äµÄÓ³Éä
Fig.5¡¡The mapping between ACSI and MMS
¡¡¡¡IEC 61850¡ª8¡ª2¶¨ÒåÁËACSIµ½Profibus FMS£¨fieldbus message specification£©Ö®¼äµÄÓ³Éä¡£
¡¡¡¡IEC 61850¡ª9¡ªX¶¨ÒåÁ˹ý³Ì×ÜÏßÒ»¼¶µÄSCSM¡£
5¡¡ÓëÆäËû±ê×¼µÄ¹ØÏµ
¡¡¡¡IEC 61850µÄÖÆ¶¨ÕßÀ´×Ô²»Í¬µØÇøµÄѧÊõ»ú¹¹ºÍ¿ç¹ú¹«Ë¾£¬ËûÃDzο¼ºÍÎüÊÕÁË´óÁ¿ÒÑÓеÄÏà¹Ø±ê×¼£¬²»Í¬µØÇøµÄ¼¼ÊõÌØµãÒ²·´Ó³ÔÚIEC 61850ÖУ¬ÕâЩ¶¼¾ö¶¨ÁËIEC 61850ÓëÒÑÓбê×¼¾ßÓÐÌìÈ»µÄÁªÏµ¡£IEC 61850²Î¿¼¡¢ÎüÊÕ²¢·¢Õ¹ÁËIEC 870¡ª5¡ª103£Û2£Ý£¬Ê¹µÃIEC 61850¡ª7¡ª2³ÉΪIEC 870¡ª5¡ª103µÄ³¬¼¯¡£IEC 61850ÖдóÁ¿Ê¹ÓÃÃæÏò¶ÔÏó½¨Ä£¼¼Êõ£¬IEC 61850¡ª8¡ª1¶¨ÒåÁËACSIµ½MMSµÄSCSMÓ³É䣬ÕâЩÏÔÈ»ÊÇÊܵ½ÁËÃÀ¹úµçÁ¦¿ÆÑ§Ñо¿ÔºUCAͨÐÅÐÒéÌåϵ£Û3£ÝµÄÓ°Ï죬Ҳ¿ÉÒÔ˵ÊDzÎÓëÖÆ¶¨IEC 61850µÄÃÀ¹úר¼Ò½«UCAÕâÖÖµØÇøÐÔÐÒéÌåÏµÍÆÏò¹ú¼Ê»¯µÄ½á¹û¡£IEC 61850¡ª8¡ª2Öиø³öÁËACSIµ½Profibus FMSµÄÓ³É䣬ÕâÊÇÊÜÅ·ÖÞ¹ú¼ÒÓ°ÏìµÄ½á¹û¡£ÔÚÅ·Ö޵ıäµçÕ¾×Ô¶¯»¯ÏµÍ³ÖÐProfibus FMSÓ¦Óúܹ㣬Òò´ËÖÆ¶¨IEC 61850±ê׼ʱŷÖÞ¹ú¼Ò´ú±íÒª¾¡Á¿±£»¤ËûÃǵÄÀûÒæ¡£
6¡¡½áÓï
¡¡¡¡IEC 61850Éæ¼°¶àÖÖм¼ÊõºÍѧ¿Æ£¬ÊǸöÅӴ󡢸´ÔÓµÄÌåϵ£¬±¾ÎĽéÉÜ¡¢·ÖÎöÁËIEC 61850ͨÐÅÐÒéÌåϵ¡£IEC 61850¶ÔÓÚÏÖÔںͽ«À´±äµçÕ¾×Ô¶¯»¯¼¼Êõ·¢Õ¹·½Ïò¶¼½«²úÉúÖØ´óµÄÓ°Ï죬Òò´ËÓбØÒª¼ÌÐø¶ÔËü½øÐÐÉîÈë·ÖÎöºÍÑо¿¡£